Changeset 3399


Ignore:
Timestamp:
Oct 30, 2012, 11:37:09 AM (18 months ago)
Author:
quozl
Message:

spiflash - two parts with different voltage have the same JEDEC ID, the Winbond W25Q16CVSSIG and W25Q16BVSIG, so render them as W25Q16, which also matches the name the vendor has used.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • dev/olpc/spiflash/spiflash.fth

    r3398 r3399  
    317317         jedec-id# h# 1520c2 =  if  2mb-flash  " MX25L1605D"   to spi-id$  then 
    318318         jedec-id# h# 1540c8 =  if  2mb-flash  " GD25Q16B"     to spi-id$  then 
    319          jedec-id# h# 1540ef =  if  2mb-flash  " W25Q16CVSSIG" to spi-id$  then 
     319         jedec-id# h# 1540ef =  if  2mb-flash  " W25Q16"      to spi-id$  then 
    320320      endof 
    321321      h# 25  of 
Note: See TracChangeset for help on using the changeset viewer.