Changeset 3325


Ignore:
Timestamp:
Sep 26, 2012, 5:44:41 AM (2 years ago)
Author:
quozl
Message:

OLPC XO-1 - test-all did "BOUND range exceeded" continuously at ok prompt after USB test, caused by bad stack balance

File:
1 edited

Legend:

Unmodified
Added
Removed
  • dev/usb2/hcd/ehci/probe.fth

    r3015 r3325  
    7575   ." Device connected - probing ... " 
    7676   probe-setup                      ( port# ) 
    77    dup probe-root-hub-port          ( port# ) 
    78    probe-teardown                   ( port# ) 
     77   probe-root-hub-port              ( ) 
     78   probe-teardown                   ( ) 
    7979   probe-error?                     ( error? ) 
    8080   dup  if  ." Failed" else  ." Done"  then  cr  ( error? ) 